EN / CN

Cell Analysis, Sorting & Monoclonal Plating Device

Cell Analysis, Sorting & Monoclonal Plating Device

Cell Analysis, Sorting & Monoclonal Plating Device

Watch the full video

Cell Analysis, Sorting & Monoclonal Plating Device

WOLF cell analysis, sorting & monoclonal plating device is an all-in-one solution for cell analysis, cell sorting and monoclonal plating offered by NanoCellect Biomedical Inc. WOLF's gentle sorting mechanism (< 2 psi), low shear stress and large particles (900nm-65μm) sorting allow for more effective sorting of rare target cells with high activity. During the sorting process, cell culture medium, PBS and even seawater can be used as sheath fluid to ensure cell viability while enhancing monoclonal sorting efficiency.

Cell Analysis, Sorting & Monoclonal Plating Device

Nondestructive sorting of fragile cells, such as primary cells, protoplasts and nucleus

Nondestructive sorting of fragile cells, such as primary cells, protoplasts and nucleus

• Purity of enriched and sorted cells >99%, cell viability >95%, cell viability 24 hours after sorting >90%, cell viability one week after sorting >85%;single-cell plating efficiency >95%, monoclonal outgrowth efficiency >90%

Can be used in biosafety level-3 labsP3

Can be used in biosafety level-3 labsP3

• With a size of a laptop, it can easily be placed into a biosafety cabinet to avoid contamination • Microfluidic sorting cartridges help avoid the risk of cross-contamination • <2psi low-pressure sorting to prevent formation of aerosols • Cartridges (>100 96-well plates for single cartridge) can automatically clean and change samples

Intelligent control throughout the process, no maintenance

Intelligent control throughout the process, no maintenance

• Integrated software for flow analysis + flow sorting, with no limitation on number of accounts. “Next-step” operation can be learned within an hour • Universal FCS3.1 format can generate scatter plots, bar plots, contour plots, heat maps and overlay plots, etc. • Index Sorting module for “one-button” tracking of monoclonal results • 100,000-hour warranty for laser with fixed optical path design, no consumable part and can be freely moved among labs • All fluid paths are embedded in cartridge, thus requiring no cleaning before shut down, and there is no need for fluid container

Nondestructive sorting of fragile cells, such as primary cells, protoplasts and nucleus Nondestructive sorting of fragile cells, such as primary cells, protoplasts and nucleus

Can be used in biosafety level-3 labsP3 Can be used in biosafety level-3 labsP3

Intelligent control throughout the process, no maintenance Intelligent control throughout the process, no maintenance

Cell Analysis, Sorting & Monoclonal Plating Device

Cell Analysis, Sorting & Monoclonal Plating Device

Application scenario

Single-cell sequencing

Single-cell sequencing

Cell line development

Cell line development

Antibody development

Antibody development

Gene editing

Gene editing

Monoclonal outgrowth of T-cell

Monoclonal outgrowth of T-cell

Monoclonal outgrowth of B-cell

Monoclonal outgrowth of B-cell

Monoclonal outgrowth of iPS

Monoclonal outgrowth of iPS

Sorting of sensitive and fragile cells

Sorting of sensitive and fragile cells

Sorting of 65μm particles

Sorting of 65μm particles

Sorting of infectious samples

Sorting of infectious samples

Technical Specifications

Product name Cell Analysis, Sorting & Monoclonal Plating Device
Sorting pressure Less than 0.138bar (1/7 bar, gentle sorting)
Principle of sorting Microfluidic cartridges-based sorting
Sample input 1.5mL tube, 5mL tube and 50mL conical tube
Sorting output 1.5mL/5mL, 96/384-well plates, 96/384-well PCR plates
Dead volume 50μL
Minimum sample volume 150μL
Sample flow rate 24μL/min
Sheath flow rate 160μL/min
Sheath fluid usage 7.5mL/hour
Fluid path flow rate 9.6mL/hour
Sorting system Sorting of stock cultures of cells, growth medium recommended, buffer not required
Cell count Absolute count, accurate to single cell
Cell sorting Cell purity > 99%, cell viability > 95%
Single-cell plating time 2-8 min (96-well plate); 9-30 min (384-well plate)
Volume of single-cell droplet 3.5-8μL
G2 dimensions and weight Side length not exceeding 40cm, 32kg
WOLF dimensions and weight Side length not exceeding 40cm, 20kg
N1 dimensions and weight 21cm×16cm×20cm, 3kg

Request a demo/brochure

Please leave your contact details and specific requirements below

Request a demo/brochure

Introduction Features Application Specifications Services

Data download

You can leave your contact information and specific needs below, we will contact you as soon as possible.

*Company name

Profession

  • Basic scientific research
  • clinical diagnosis
  • Biotechnology
  • Pharmaceutical R&D
  • other

*Contact person

Position

*Telephone

E-mail

Product trial application

You can leave your contact information and specific needs below, we will contact you as soon as possible.

*Company name

Profession

  • Basic scientific research
  • clinical diagnosis
  • Biotechnology
  • Pharmaceutical R&D
  • other

*Contact person

Position

*Telephone

E-mail

*Requirement

*Experimental

0086-21-34121223/131 6273 6602

We use cookies to help provide you with the best possible online experience. Please read our Privacy Policy & Cookies for information about which cookies we use and what information we collect on our site. By continuing to use this site, you agree that we may store and access cookies on your device.

Add:

BioHandler Shanghai headquarters:

Unit 306B, Block 6, Zizhu Science Park, No. 555, Dongchuan Road, Minhang District, Shanghai

Beijing company:

Unit 602, Block A2, Yongfeng Industrial Park Zhongguancun No. 1, Haidian District, Beijing

Guangzhou office:

Unit A303, Ruiyue Automotive Electronics Innovation Park, No. 1, Nanxiang Sub-road, Huangpu District, Guangzhou

Tel:

0086-21-34121223/131 6273 6602